Technical Data Sheet (PDF)
- UL recognized component
- Communication through LONWORKS® AND Modbus® (RS-232/485)
- 3-phase power metering and monitoring of voltage, current, power factor, kW, kWh, kVa, kVAh, kVAR, kVARh, harmonic distortion (THD, TOHD, TEHD and individual harmonics 2 to 15), and A-phase frequency, aux frequency
- Integral load-shedding algorithms manage power consumption
- True RMS metering accuracy for voltage, current, power and energy
- 8 individually isolated, programmable, dry contact outputs
- 8 individually isolated, programmable discrete inputs (AC or DC), each input selectable for low or high voltage
- 2 programmable, analog outputs that connect to PLCs, SCADA systems, panel meters, data recorders, etc.
- Setup and configuration using a standard PC interface
- Intuitive set-up tailors device to application thus saving time
- 0.2% accuracy, current, and voltage
- Flexibility to operate as a stand-alone or integrate with a snetwork
- Easily integrates with energy management, BSA and SCADA systems
- External power supply not required (device operates on power being metered)
The Meter Monitor Control™ is a full-featured, configurable metering and monitoring control. The open communications network, integral load-shedding algorithms and inherent ease-of-use make this device perform. Combined with our 2-year standard warranty and 24-hour technical support, the Meter Monitor Control™ is the complete solution to all power metering and monitoring needs.
- Includes Network Service Tool (NST) setup and configuration tool for LONWORKS® -based hardware
- Store parameters for easy transfer between units
- 32-bit application, Windows® 95 and NT® 4.0 compatible
- Runs on standard desktop or laptop PC, eliminating the need for a hand-held programmer
- Basic monitoring functions built in
- Simple “drag-and-drop” interface
- Reads and displays LONMARK® object names
- Utilizes simple user-created forms
- Industry standard ODBC-compliant database
- High-speed OLE automation server
- Reads and displays values and documentation for monitored data points Protective Relaying Functions
- Sync check (25)
- Auto-synchronizer (25A) w/ voltage matching, two modes available:
- Frequency and phase matching
- Slip frequency
- Over/under voltage for generator and utility tie (27/59)
- Over/under frequency for generator and utility tie (81 O/U)
- Directional power (32)
- Directional reactive power (32VAR)
- Reverse-phase/phase-balance current (46)
- Phase sequence voltage (47)
- Voltage-restrained overcurrent (51VR)
Humidity: 95% at 38° C Temperature: -25°C to 70° C
18 to 75 Vdc (<10W) 85-265 Vac (<25W)
60-150 Vac; 50/60 Hz; delta, open delta or wye configurations
60-150 Vac; 50/60 Hz; delta, open delta or wye configurations
0-5 Amps; 50/60 Hz
0-5 Amps; 50/60 Hz
20-40 Vac/Vdc; 85-150 Vac/Vdc
1-120 Vac/Vdc; 0.15 Amps Max
+/- 3 Vdc and 4-20 mA Designed to meet or exceed ANSI/IEEE C37.90-1989, IEEE Standards for Relays and Relay Systems Associated with Electrical Power Apparatus (5000 Volt Surge Withstand)
IEC 1000-4-2 Electrostatic Discharge IEC 1000-4-3 Radiated Immunity IEC 1000-4-4 Fast Transient IEC 1000-4-5 Surge Withstand IEC 1000-4-6 Conducted Immunity ANSI/IEEE C37.90.1 Surge Withstand/Fast Transient ANSI/IEEE C37.90.1 Radiated Immunity
Designed for LONMARK® Compatibility
Recognized to U.S. and Canadian requirements under the Component Recognition Program of Underwriters Laboratories Inc.
|